Frequently Asked Questions .& Answers with Static single to three phase converters


What is the main advantage of a Static converter over a Rotary converter?
The static converter works best on single motor applications that have a weak supply network or input voltages equal to or less than 240v. It also supplies the center phase progressively as the three phase motor picks up in speed which has minimal supply disturbance and a smooth start feature to the three phase motor.

How do you select the best setting on a Power Level Switch?
The optimum setting is determined with the motor running and selected for a balanced voltage across phases.

Can I use a Static converter on three phase welders?
No, Rotary converters only.

What about multiple motors?
Yes , but the auxillary motor must only be in operation when the main motor is running , for example on a three phase lathe operated by a Static converter you would need to start the main motor and once up to speed the lube pump can be turned off and on at will.

Can I use a Static converter for compressors amd submersible pumps?
No, static converters are limited to loads generally experienced with machine tools ie. have a starting current requirement of less than 3 x the full load current rating of the motor operated.

Does it consume any more power than it would on thre phase?
Static converters consume minimal current off load and on load the only real losses or consumption of the converter is in heat losses, this works out to only a few percent.

What size KVA transformer is required?
As a guide one KVA per HP of three phase load to be operated at one time.

Where do I install the converter?
It needs to go into an enclosed area with adequate ventallation to allow for cooling and protection from the weather ie. shed or workshop etc.. The best option is to mount the converter as close as possible to the loads operated.

Does your inverter produce line interference or harmonics?
Firstly the POLYPHAZ unit is not an inverter it is a converter and as such does not contain high speed switching devices that can distort the input power supply and produce harmonics, as a result of this the POLYPHAZ converter can utilize a 100% of the supply transformer capacity unlike inverters which have a rating to supply transformer ratio of approx. 10% of the supply capacity transformer unfiltered as per AS2279 part two.